OUTLINE DIMENSIONS

SPECIFICATION
|
Rated
Capacity:
|
(Kg)
|
50
|
|
Rated Output:
|
(mv/v)
|
2.0±0.10%
|
|
Zero Balance:
|
(%R.O.)
|
±2
|
|
Non-linearity:
|
(%R.O.)
|
±0.02
|
|
Non-repeatability:
|
(%R.O.)
|
±0.015
|
|
Hysteresis:
|
(%R.O.)
|
±0.02
|
|
Creep:
|
(%R.O./5min)
|
±0.02
|
|
Temperature Effect on Zero
|
(%R.O./10℃)
|
0.03
|
|
Temperature Effect on Output
|
%R.O./10℃)
|
0.03
|
|
Input Resistance:
|
(Ω)
|
1130
|
|
Output Resistance:
|
(Ω)
|
1000
|
|
Insulation Resistance:
|
(MΩ)
|
≥5000
|
|
Recommended excitation voltage:
|
(V)
|
5 to 12(DC)
|
|
Operating temperature range:
|
(℃)
|
–10 to +40
|
|
Safe Overload:
|
(% R.C.)
|
150
|
|