ELC-SB20

Features
  • Alloy steel, surface bluing treatment, spray painted, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments.
  • Small size, low profile, small deflection, compact stainless steel
    construction and a structural integrity capable of withstanding extraneous loads
  • High permissible dynamic load
  • Fully welded, providing IP 67 protection
Specifications

Accuracy class

 0.3

 0.1

Maximal capacity (Emax)

Weight (G), approx.

 kg
 
 kg

 25;50

 0.3

 100;200;300;500;
 1,000;2,000
 0.5

5,000

2.2

10,000

2.6

20,000

4.1

30,000

7.8

Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin)  *
Repeatability (drep)  *
Hysteresis error (dhy) *
Creep (dDR)in 30 min.
Input resistance (RLC) [Red(+)-black(-)]
Output resistance (RO) [Green(+)-white(-)]
Reference excitation voltage (Uref)
Maximal excitation voltage
Insulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range

mV/V
mV/V
% of Cn/k
% of Cn/k
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)

°C°F
°C°F
°C°F

2±1%
±0.04
< ±0.0023
< ±0.0120
< ±0.2
< ±0.3
< ±0.1
< ±0.1
400 ±25
350±3
0.5…12
18
>2[50 VDC ]
-10…+40[15…+105]
-30…+70[-5…+122]
-25…+70[-13…+158]

2±1%
±0.04
< ±0.0023
< ±0.0120
< ±0.05
< ±0.1
< ±0.03
< ±0.05
770 ±30
700±5
0.5…24
36
>2[50 VDC ]
-10…+40[15…+105]
-30…+70[-20…+160]
-50…+85[-60…+185]

Safe load limit (EL)
Breaking load (Ed)

% of Cn
% of Cn

  150
  300

Protection class (IP) acc. to IEC529

 

  IP67

Outline Dimension mm

ELC-SB20 Dimensions

 

 

 

||  Homepage of Elane ||             ||  Back to Load Cell ||